Tactical Distribution Fiber

Features
& Benefits
 |
Thinnest profile of tactical cable types |
 |
900u TIght Buffer fiber coatings with overall armid filler |
 |
Crush-resistant |
 |
Helically
stranded cable core for superior mechanical protection and flexibility |
 |
For Tactical ENG, Broadcast, Military or Staging Applications |
 |
Mil-Spec Compliant |
 |
Round Polyurethane
jacketed for abrasion, cut and chemical resistance. |
 |
2
to 24 fibers, higher fiber counts are available on request. |
| Single-Mode: Tactical Distribution Fiber |
| Fiber Count |
Part
Number |
Diameter
mm (in) |
Weight
kg/km
(lbs/1,000') |
Short-Term
Tensile Load
(lbs) |
Long-Term
Tensile Load
(lbs) |
| 2 |
CWF-DMT002SM |
5.0
(.20) |
23
(15) |
1,800
(400) |
600
(130) |
| 4 |
CWF-DMT004SM |
5.5
(.22) |
28
(19) |
1,800
(400) |
600
(130) |
| 6 |
CWF-DMT006SM |
6.0
(.24) |
28
(19) |
1,800
(400) |
600
(130) |
| 8 |
CWF-DMT008SM |
6.5
(.26) |
38
(26) |
1,800
(400) |
600
(130) |
| 10 |
CWF-DMT010SM |
6.5
(.26) |
45
(30) |
2,100
(470) |
700
(160) |
| 12 |
CWF-DMT012SM |
6.5
(.26) |
51
(34) |
2,100
(470) |
700
(160) |
| 18 |
CWF-DMT018SM |
7.5
(.30) |
60
(40) |
2,400
(540) |
800
(180) |
| 24 |
CWF-DMT024SM |
8.5
(.33) |
74
(50) |
3,000
(670) |
1,000
(220) |
Multi-Mode: Tactical Distribution Fiber
|
| |
Tensile
Load Rating |
| Fiber
Count |
Part
Number |
Diameter
mm (in) |
Weight
kg/km
(lbs/1,000') |
Short-Term
N
(lbs) |
Long-Term
N
(lbs)
|
| 2 |
CWF-DMT002MM |
5.0
(.20) |
23
(15) |
1,800
(400) |
600
(130) |
| 4 |
CWF-DMT004MM |
5.5
(.22) |
28
(19) |
1,800
(400) |
600
(130) |
| 6 |
CWF-DMT006MM |
6.0
(.24) |
28
(19) |
1,800
(400) |
600
(130) |
| 8 |
CWF-DMT008MM |
6.5
(.26) |
38
(26) |
1,800
(400) |
600
(130) |
| 10 |
CWF-DMT010MM |
6.5
(.26) |
45
(30) |
2,100
(470) |
700
(160) |
| 12 |
CWF-DMT012MM |
6.5
(.26) |
51
(34) |
2,100
(470) |
700
(160) |
| 18 |
CWF-DMT018MM |
7.5
(.30) |
60
(40) |
2,400
(540) |
800
(180) |
| 24 |
CWF-DMT024MM |
8.5
(.33) |
74
(50) |
3,000
(670) |
1,000
(220) |
|
|
| Mechanical Characteristics |
Minimum Bend Radius
(Installation Tensile Load) |
16x
outside
Diameter |
Minimum Bend Radius
(Long-Term Tensile Load) |
8x
outside diameter |
| Operating
Temperature |
-55°C
to+85°C |
| Storage
Temperature |
-70°C
to +85°C |
Crush
Resistance
(TIA/EIA-455-41 mil requirement) |
440
N/cm |
Impact
Resistance
(EIA/TIA-455-25 mil. requirement |
200
impacts |
Flex
Resistance
(TIA/EIA-455-104 mil. requirement) |
2,000
cycles |
| These
specifications are subject to change without prior notification |
|
| © 2011 Clark Wire & Cable
1-800-CABLE-IT (800-222-5348) |
|