Return to the Clark Homepage
 
 


M-Series Messenger Cables Product Specifications
Click to View
Light
Medium
Heavy
   
How to Use the Product Specifications Charts
Determine the desired fiber count, span length (pole spacing) and storm load rating for your application. Select the chart which describes your NESC Storm Load Rating (from the map below) and the desired cable style. Enter the selection chart from the left, selecting the row for the appropriate fiber count. Then go across this row until you reach the number equal to or greater than the desired span length in meters. At the bottom of this column is the "Messenger Designation: for the desired cable. Complete the part number suffix with this Messenger Designation and the selection of strength member.
   
Example

If the application is in Florida, the storm load map indicates that this is NESC Storm Load Rating "Light". Considering the prevalence of thunderstorms, the Dielectric Messenger is chosen from the chart below. If the requirement id for an 8-fiber cable, with the longest span length being 65 meters, enter the chart from the left (at 8 fibers), go across that row to "70", the next higher span length, and down that column to the letter "E". The part number suffix then becomes "-EDS" (Messenger Designation"E" with dielectric strength member "DS").
  
NESC (Medium) SS/GS Steel Messenger
Fiber Count Span Length (meters)
2 40 60 90 125 160 200
4 40 60 90 125 160 200
6 40 60 90 125 160 200
8 40 60 90 125 160 200
12 38 55 85 115 150 190
18 38 55 85 115 150 190
24 38 55 80 110 140 180
36 30 50 75 105 135 170
48 27 45 68 95 125 160
60 25 45 68 95 125 155
72 24 40 65 89 117 150
84 - 40 61 85 110 145
96 - 38 60 80 105 140
    E F G H I J
Messenger Designation

NESC (Medium) Dielectric Messenger
Fiber Count Span Length (meters)
2 25 45 75 95 110 120
4 25 45 75 95 110 120
6 25 45 75 95 110 120
8 25 45 75 95 110 120
12 22 41 70 90 105 115
18 22 41 70 90 105 115
24 21 40 66 85 100 110
36 20 40 62 80 100 105
48 - 36 57 75 90 95
60 - 35 55 70 85 90
72 - - 53 68 80 85
84 - - 51 67 78 85
96 - - 50 62 73 80
   E F G H I J
Messenger Designation
   
Strength Member Size Messenger Part Number Designation
Strength Member Type D E F G H I J X
Stainless Steel (SS)
Galvanized Steel (GS)
- 3/32
(2.4 mm)
1/8
(3.2 mm)
5/32
(4.0 mm)
3/16
(4.8 mm)
7/32
(5.6 mm)
1/4
(6.4 mm)
Customer Specify
Dielectric Strength
Member (DS)
.080
(2.0 mm)
.098
(2.5 mm)
.130 (3.3 mm) .157
(4.0 mm)
.177
(4.5 mm)
.197 (5.0 mm) - Customer Specify
   
NESC (Heavy) SS/GS Steel Messenger
Fiber Count Span Length (meters)
2 20 35 50 70 95 120
4 20 35 50 70 95 120
6 20 35 50 70 95 120
8 20 35 50 70 95 120
12 18 35 46 70 95 120
18 18 35 46 70 95 120
24 17 35 46 65 85 110
36 17 30 42 65 80 105
48 15 28 40 57 76 95
60 15 28 40 57 76 95
72 14 24 38 55 70 90
84 - 24 38 53 68 89
96 - 23 35 50 66 85
   E F G H I J
Messenger Designation

   
NESC (Heavy) Dielectric Messenger
Fiber Count Span Length (meters)
2 15 27 42 55 65 70
4 15 27 42 55 65 70
6 15 27 42 55 65 70
8 15 27 42 55 65 70
12 13 25 40 53 62 65
18 13 25 40 53 62 65
24 12 24 40 52 60 62
36 11 24 36 47 54 60
48 - 23 33 45 52 55
60 - 23 33 45 52 55
72 - - 30 40 50 52
84 - - 30 40 50 52
96 - - 30 38 45 48
   E F G H I J
Messenger Designation
 
 