Outer
ferrule |
Bushing* |
Male
contact |
Plug
body
assembly |
Female
contact |
Jack
body
assembly |
* for
use on RG-62, 71, 210 cable only
|
ConnectorType:
75
BNC Plug
|
|
Connex / ADC
No.
& Clark Cable No.
|
Hex
Crimp Data |
Contact For Connex/ADC |
Cavity
for
Outer Ferrule |
Die
Set for
Tool-1 |
Tool
No. |
BNC-112119 / BNC-2-N
Clark RG59B/U |
.068 |
.255 |
DIE-1 |
TOOL-1
|
.042 |
BNC-112507 / BNC-1-N
Clark CV7559, RCC Series |
.068 |
.255 |
DIE-1 |
TOOL-1
|
.042 |
BNC-112509 / BNC-4-N
Clark CV752 |
.068 |
.324 |
DIE-1 |
TOOL-1
|
.042 |
BNC-112521 / BNC-13
DSM1 |
.068 |
.178 |
DIE-8 |
TOOL-8 |
.042 |
BNC-112521 / BNC-8
RG6SD
|
.068 |
.278 |
DIE-8 |
TOOL-8 |
.042 |
|
Step 1 :
Strip cable jacket, braid, and dielectric to dimensions in table below.
[for RG-62,71, & 210/U cables, trim an additional .039"(1.0mm) of insulation
off center conductor and add bushing]
Slide outer ferrule onto cable as shown.
Important: Do not nick braid, dielectric, and center conductor.
All cuts are to be sharp and
square.
|
Strip Dimensions For Connex BNC's |
Strip Dimensions For ADC BNC 's |
|
a .593 (15.1)
b .250 (6.4)
c .156 (4.0)
Ferrule

|

|
|
For RG-174,
179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm)
as shown.
Before attaching center contact TFE sleeve (not shown)
over cable dielectric and under braid.
For 31-71016, before
attaching center contact. Slide metal spacer/TFE sleeve (not
shown)
over cable dielectric and under braid.
The center contact
should butt against the dielectric and TFE sleeve. |
Step 2
Flare slightly end of cable braid as shown to facilitate insertion
of inner ferrule.
Important: Do not comb out braid.
Place contact on cable center conductor so that it butts against cable
dielectric.
Crimp contact in place using Die Set Cavity indicated
in table above.
When using RG-62, 71, 210, install bushing over center
conductor before installing contact.
|
contact
must butt against cable dielectric
 |
outer
ferrule
should
butt here cable
dielectric must butt insulator |
|

|
|
|
|